Home  /  Products  /  Air-Cooled Low-Temperature Industrial Chiller
Air-Cooled Scroll Low Temperature Chiller (-5℃-30℃)
  • Air-Cooled Scroll Low Temperature Chiller (-5℃-30℃)
  • Air-Cooled Scroll Low Temperature Chiller (-5℃-30℃)

Air-Cooled Scroll Low Temperature Chiller (-5℃-30℃)

Can be customized acid-proof, anti-corrosion, frequency conversion, explosion-proof. DX-AL series air-cooled low-temperature chillers are a new generation of low-temperature refrigeration equipment carefully designed and developed by Dongxing Refrigeration Company for pharmaceutical, chemical and other special industries. The temperature range can be adjusted arbitrarily between -5°C and -30°C. The compressor of the small horse number model adopts the French "Maneurop"

Share
  • Features
  • Parameters

Can be customized acid-proof, anti-corrosion, frequency conversion, explosion-proof. DX-AL series air-cooled low-temperature chillers are a new generation of low-temperature refrigeration equipment carefully designed and developed by Dongxing Refrigeration Company for pharmaceutical, chemical and other special industries. The temperature range can be adjusted arbitrarily between -5°C and -30°C. The compressor of the small horse number model adopts the French "Maneurop", and the large horse number model adopts the international famous brand (Taiwan Han Bell, Zell) Screw compressors, air-cooled low-temperature chillers have sufficient refrigeration and complete specifications, which are a model of a new generation of refrigeration equipment.

DX-AL series air-cooled low-temperature chillers are a new generation of low-temperature refrigeration equipment carefully designed and developed by Dongxing Refrigeration Company for pharmaceutical, chemical and other special industries. The temperature range can be adjusted arbitrarily between -5°C and -30°C. The compressor of the small horse number model adopts the French "Maneurop", and the large horse number model adopts the international famous brand (Taiwan Han Bell, Zell) Screw compressors, air-cooled low-temperature chillers have sufficient refrigeration and complete specifications, which are a model of a new generation of refrigeration equipment.

Technical parameters of DX-AL low temperature chiller (-5℃)

Model itemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h3327518482411160714,3151741023214186312669638691
kw3.876.039.5813.516.6520.252733.331.0545
Input total powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
The refrigerantnameR22
way to controlExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530
Condenser










<, /SPAN> 
typeHigh efficiency copper tube sleeve aluminum fin type + low                     noise external rotor fan
EvaporatortypeWater tank coil (shell and tube type)
Chilled water volume (m3/h)0.721.111.772.53.083.754.996.615.748.32
Inlet and outlet pipe diameter1"1"1"1-1/2″1-1/2″2"2"2-1/2″2-1/2″3″
Water pumpPower (KW)0.750.750.751.11.11.52.22.244
Head (M)18181820202020202520
safety protectionCompressor overload protection, over current protection, high                     and low pressure protection, over temperature protection, flow protection, phase sequence/phase                     loss protection, exhaust overheating protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975104012701280128016801720191420262250
Machine weightKg13517531045053075083592010801125

Technical parameters of DX-AL low temperature chiller (-10℃)

Model itemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h2514402367329440116841416018881233692011929405
kw2.924.687.8310.9813.5916.4721.9627.1823.434.2
Total input powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
refrigerantnameR22
Control methodExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530
Condenser












typeHigh efficiency copper tube sleeve aluminum fin type + low noise external rotor fan
EvaporatortypeWater tank coil (shell and tube)
Chilled water volume (m3/h)0.550.881.482.82.583.124.175.164.446.49
Inlet and outlet pipe diameter1″1″1″1-1/2″1-1/2″2″2″2-1/2″2-1/2″3″
Water PumpPower (KW)0.750.750.751.11.11.52.22.244
Lift (M)18181820202020202520
Security protectionCompressor overload protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975104012701280128016801720191420262250
Mechanical weightKg13517531045053075083592010801125

DX-AL low temperature chiller technical parameters (-15℃)

Model ItemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h23213985549480471002011994160952008822271129018
kw2.74.636.399.3611.6513.9518.7223.326.4133.75
Total input powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
refrigerantnameR22
Control methodExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530
Condenser












typeHigh efficiency copper tube sleeve aluminum fin type + low noise external rotor fan
EvaporatortypeWater tank coil (shell and tube)
Chilled water volume (m3/h)0.540.931.281.872.332.793.744.665.286.75
Inlet and outlet pipe diameter1″1″1″1-1/2″1-1/2″2″2″2-1/2″2-1/2″3″
Water PumpPower (KW)0.750.75 ,0.751.11.11.52.22.244
Lift (M)18181820202020202520
Security protectionCompressor overload protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975104012701280128016801720191420262250
Mechanical weightKg13517531045053075083592010801125

DX-AL low temperature chiller technical parameters (-20℃)

Model ItemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h18103095429463457931724212690158631709321821
kw2.13.64.997.389.228.4214.7618.4519.8825.38
Total input powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
refrigerantnameR22
Control methodExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530
Condenser












typeHigh efficiency copper tube sleeve aluminum fin type + low noise external rotor fan
EvaporatortypeWater tank coil (shell and tube)
Chilled water volume (m3/h)420.7211.481.851.692.963.73.995.1
Inlet and outlet pipe diameter1″1″1″1-1/2″1-1/2″2″2″2-1/2″2-1/2″3″
Water PumpPower (KW)0.750.750.751.11.11.52.22.244
Lift (M)18181820202020202520
Security protectionCompressor overload protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975104012701280128016801720191420262250
Mechanical weightKg13517531045053075083592010801125

DX-AL low temperature chiller technical parameters (-25℃)

Model ItemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h1005158433104651430751848628105701243515863
kw1.171.843.855.415.016.0310.0312.2914.4618.45
Total input powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
refrigerantnameR22
Control methodExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530
Condenser












typeHigh efficiency copper tube sleeve aluminum fin type + low noise external rotor fan
EvaporatortypeWater tank coil (shell and tube)
Chilled water volume (m3/h)0.250.390.621.151.061.282.122.63.063.91
Inlet and outlet pipe diameter1″1″1″1-1/2″1-1/2″2″2″2-1/2″2-1/2″3″
Water PumpPower (KW)0.750.750.751.11.11.52.22.244
Lift (M)18181820202020202520
Security protectionCompressor overload protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975104012701280128016801720191420262250
Mechanical weightKg13517531045053075083592010801125

DX-AL low temperature chiller technical parameters (-30℃)

Model ItemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h650998220532192955345860597265964310988
kw0.751.162.563.743.434.027.048.4510.0512.76
Total input powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
refrigerantnameR22
Control methodExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530
Condenser












typeHigh efficiency copper tube sleeve aluminum fin type + low noise external rotor fan
EvaporatortypeWater tank coil (shell and tube)
Chilled water volume (m3/h)0.160.250.560.820.750.881.551.862.222.82
Inlet and outlet pipe diameter1″1″1″1-1/2″1-1/2″2″2″2-1/2″2-1/2″3″
Water PumpPower (KW)0.750.750.751.11.11.52.22.244
Lift (M)20202020202020202520
Security protectionCompressor overload protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975104012701280128016801720191420262250
Mechanical weightKg13517531045053075083592010801125

DX-AL low temperature chiller technical parameters (-35℃)

Model ItemDX-03ALDX-05ALDX-08ALDX-10ALDX-12ALDX-15ALDX-20ALDX-25ALDX-30ALDX-40AL
Cooling capacitykcal/h37168013152066232141784604595873128434
kw0.430.791.532.42.74.865.357.938.59.81
Total input powerKW3.184.867.259.410.913.4718.822.5528.536
power supply3PH 380V 50HZ
refrigerantnameR22
Control methodExternally balanced thermal expansion valve
compressortypeFully enclosed scroll type (piston type)
Power (KW)2.253.7567.5911.257.5*29.37*222.530

Condenser

typeHigh efficiency copper tube sleeve aluminum fin type + low noise external rotor fan
EvaporatortypeWater tank coil (shell and tube)
Chilled water volume (m3/h)0.090.170.330.530.591.071.18,1.8531.872.16
Inlet and outlet pipe diameter1″1″1″1-1/2″1-1/2″2″2″2-1/2″2-1/2″3″
Water PumpPower (KW)0.750.750.751.11.11.52.22.244
Lift (M)20202020202020202520
Security protectionCompressor overload protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection.
Mechanical DimensionsLength (mm)930114013101680168018002000200022002500
Width (mm)5205607208108109901130113011301200
Height (mm)975, /P,10401270128012801680, 1720191420262250
Mechanical weightKg13517531045053075083592010801125

 


Related Products View More +

Contact
  • E-mail: szwj1688@163.com
  • Tel: +86 0755 8171 5045
  • Phone: +86 139 2346 4030
  • Fax: +86 0755 8171 5085
  • Wechat: +86 139 2346 4030
Follow Us

All Rights Reserved | Sitemap

WeChat