Analysis of the reasons for the industrial cold water machine alarm
2016-12-12 09:04:07http://www.szdxj.com admin
        Industrial cold water machine in the running process, often in the emergence of the phenomenon of refrigeration at the same time, there is no warning, so that the operator can not start, do not know what is the cause of this problem. East Star to do a case analysis of this phenomenon, I hope to help the majority of users, as soon as possible to solve the problem, to restore the daily use of cold water machine.
According to the East Star refrigeration maintenance personnel oral, small series will be cold water machine and no alarm prompted the reasons for the analysis summarized as follows:
        1, R22 is not enough freon refrigerant, we often say. In the chiller operation process, the liquid refrigerant in the evaporator to absorb the heat from the water stop and start after evaporation, compressor and expansion valve throttling, it becomes a low-temperature and low-pressure refrigerant into the evaporator loop to continue. If the use of a long time the refrigerant will be volatile, and then affect the cooling effect. There is also a reason for the leakage of refrigerant, which is not enough to affect the refrigeration, therefore, the cold water machine operator should observe whether the refrigerant is enough. In case of leakage of refrigerant, it is recommended to contact the cold water machine manufacturer arrange leak trap, adding enough refrigerant.
        2, the condenser for a long time is not cleaned, the condenser is one of the main components of the water chiller. Most of the cooling water contains calcium, magnesium ion and acid carbonate. When cooling water flows through the metal surface, there is the formation of carbonate. In addition, the dissolved oxygen in cooling water will cause corrosion, rust formation. Due to the production of rust scale, the heat exchange efficiency of the condenser is reduced, and the fouling is serious, which can block the pipe, so that the heat transfer effect is lost, thereby affecting the cooling effect. Therefore, it is recommended to clean the condenser once every six months.
        3, dry filter clogging. When the filter is blocked, the effect of heat transfer of the condenser is affected, and the cooling effect of the whole machine is not good, therefore, the filter is required to be checked regularly and the filter is blocked seriously.
        4, excessive water impurities, attached to the inner wall of the water pipe, resulting in insufficient water supply, thereby affecting the cooling effect. Therefore, for the region of poor water quality, it is recommended to do water treatment works or regular cleaning and replacement of water pipes, to ensure the normal operation of the cold water.
        In addition, the chiller selection must be accurate. Model is not in place, the same will not achieve the requirements of the cooling effect. I suggest that the majority of users in the purchase of water chiller, cooling capacity and other parameters will need to be provided to producers of cold water machine, cold water machine, discuss and draw the model, determine the installation scheme of cold water machine, achieve the expected effect of the refrigeration, to improve production efficiency.

24小时服务电话:400-041-8118

销售专线:13923464030

公司电话:0755-81715045  0755-81715587

公司传真:0755-81715085

公司邮箱:szwj1688@163.com

公司官网:www.szdxj.com www.szdxzl.cn

工厂地址:深圳市龙华区观澜樟坑径下围工业区一路东星产业园


  • official micro letter

  • official microblogging

Feedback在线留言
Copyright; Shenzhen City, East Star Refrigeration Technology Co., Ltd. Guangdong -2 09046816 ICP